Contact

We are gladly available for you on Monday to Thursday from 7:30 a.m. to 5:00 p.m. and Friday from 7:30 a.m. to 4:00 p.m.

+ 49 6204 6069-0

Your message

TP2406-230

TP2406-230

Product description

  • Multi loop power controller with 24 outputs
  • Output voltage 230VAC, max. 8A (per output)
  • One fuse element is provided per channel; replacement possible in case of fuse failure
  • Integrated control electronics and heat sink
  • Removable connectors for mains supply and heating outputs
  • Speed controlled ventilation fan
  • Reaction-free measurement of heating currents
  • Full-wave control or half-wave control with switch-on diagnosis (short-circuit detection)
  • Mains voltage measuring and monitoring
  • Constant power output due to automatic compensation for mains voltage fluctuations
  • Half-wave or full-wave control with connecting diagnosis (short-circuit detection)
  • Soft start mode to limit the inrush current
  • Two mounting variations available: directly on the back wall of the control cabinet or on the line bar

Product information

Technical specifications

General Data

Product nameTP2406-230
Product descriptionpower controller for the THYPO system
Item no.89181304-00 – Back wall mounting variation
89181304-01 – Line bar mounting variation
 
Item designation according to DIN EN 81346-2Q
 

Electronics

Supply voltage24VDC ±10% (supply via ribbon cable from CI head module, PELV)
Power consumptionmax. 2.5 W

Load outputs supply

Mains voltage400VAC (~/N = 230VAC) 3~/N/PE TN/TT
Mains frequency50Hz/60Hz
Mains voltage tolerance+29%, -14%
Switching capacity per phasemax. 48 A
Connector clamplockable screw terminal / min. 0.5 ...max. 16 mm2 / min AWG22...AWG.4
 

Load outputs

Controlhalf-wave and full-wave control with connecting diagnosis and optional soft start (power compensation can be switched on)
Number of outputs24 (8 per phase)
Output voltage230VAC (see mains voltage)
Output current / outputmax. 8A at 25°C ambient temperature (maximum switching capacity per phase)
Derating output current / outputmax. 7A at 55°C ambient temperature and 100% ED (derating fuse)
Type of loadresistive load
Short-circuit and overload protectionfuse 6,.x32mm / 8A / 250VAC (switch-off range g)
(Siba type 7006584.8)
Melting integral<30 A2s
Connectorlockable spring pull / 0.25 mm2....max. 2.5 mm2
 

Display

Status LEDred (error)
green (flashing = boot loader, continuous light = okay)
System bus LEDred (system bus not running)
blue (system bus communication)
LEDs load outputred (load output error)
green (load control)
 

Protection/monitoring functions

Heat sink temperatureyes (alarm at 95°C, load disconnection at 105°C)
Fuse failureyes
Mains voltage monitoring/measurementyes (see below)
Overload/short-circuit load outputyes
Missing load / broken wireyes
Short-circuit triacyes
 

Current measuring

Resolution0,1 A (accuracy ±0,1A)
Measuring range0 … 16.0 A
Measured valueper load output
Measuring methodsummation current transformer, virtually reaction-free
Performance measurementcalculation with current/voltage measurement
 

Voltage measurement

Resolution0,5 VAC (accuracy ±1VAC)
Measuring range0…253 VAC
Measuring methodTrue RMS
Measured valueper phase
 

Digital input

Quantity1
Electrical data0...30VDC, <10mA at 24VDC (optocoupler)
Functionload disconnection

Digital output

Quantity1
Electrical data25VAC, 48VDC / 1A (potentialfreier Kontakt) ohmsche und induktive Last
Functionalarm output (configurable)
 

Communication

System busCAN (via flat ribbon cable)
Addressing modeDIP switch (address 1...63)
Bus terminationautomatic
 

Mechanics

Installation positionvertical
Minimum distancesside 0 mm, top 100 mm, bottom 100 mm
Mounting methodmounting plate or line bar
Type of ventilationself-ventilation (temperature controlled)
Sound pressure level<50dB
Ingress protectionIP 20
Depth209 mm (without connector)
Height334 mm (without mounting brackets, without supply connector)
Width90 mm

Electr. safety / EMC

Electrical safetyIEC 61010-1: 2010 / Amendment 1 (2017), EN 61010-1: 2010, IEC 61010-2-201 (2017) Ed.2, EN 61010-2-201: 2013
EMCemitted interference according to EN 61000-6-4, interference immunity according to EN 61000-6-2, (industry)
Over-voltage categoryIII
Ingress protectionI
 

Environmental conditions

Ambient temperature0....+55°C
Storage / transport temperature-25...+70°C
Air pressure860...1080 hPa
Humidityat 25°C / max. 95%
at 50°C / max. 50%
interpolated linearly in between
Pollution degree2
Installation altitude above sea levelmax. 2000 m
 


Download

In the Media & Downloads section you will find an overview of all product-specific documents. 
For technical data like e.g: User guides, service manuals, etc. please register.

To media & downloads

Log in

Are you already a customer?

Do you already have a login for the PSG or Meusburger portal? Then simply log in here with the same login details:

Forgot your password?

Please enter your email address.
We will send you a new password.